BQBKS - SOLUTION S0127 PHC-1 (INDICATOR)
- MSDS: BQBKS
- Manufacturer: NALCO CHEMICAL COMPANY
- Product Name: SOLUTION S0127 PHC-1 (INDICATOR)
- National Stock Number: 6810-00N023978
Product Identification
Product ID:SOLUTION S0127 PHC-1 (INDICATOR)
MSDS Date:05/19/1989
FSC:6810
NIIN:00N023978
MSDS Number: BQBKS
Responsible Party
NAPERVILLE, IL 60563-1198
US
Emergency Phone: 708-920-1510
Info Phone: 708-305-1000
Preparer: RICKY A. STACKHOUSE
Cage: 89524
Contractor
Telephone: (630) 305-1000
Cage: 89524
Ingredients
GARBAGE COLLECTION CONTAINERS.
RTECS: 9999999ZZ
(ORAL,RAT)7060
CAS: 64-17-5
RTECS: KQ6300000
Fraction By Weight: 56%
OSHA PEL 1000 PPM
ACGIH TLV: 1000 PPM
Hazards
LD50 LC50 Mixture:SEE INGREDIENT 1.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE/SKIN:MAY CAUSE IRRITATION
W/PROLONGED CONTACT. INGEST:CAN CAUSE BLINDNESS. CAN CAUSE CNS
DEPRESSION, NAUSEA, DIZZINESS, VOMITING OR UNCONSCIOUSNESS
DEPENDING ON LENGTH OF EXPOSURE & ON FIRST AID A CTION GIVEN. CAN
BE HARMFUL. INHAL:PROLONGED INHAL OF MIST/VAPOR MAY CAUSE NAUSEA,
DIZZINESS, LIGHT- (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:HEADEDNESS, VOMITING OR
UNCONSCIOUSNESS DEPENDING ON LENGTH OF EXPOSURE & FIRST AID ACTION
GIVEN.
Medical Cond Aggravated by Exposure:A REVIEW OF AVAILABLE DATA DOES NOT
IDENTIFY ANY WORSENING OF EXISTING CONDITIONS.
First Aid
First Aid:EYE:IMMED FLUSH FOR @ LST 15 MIN WHILE HOLDING EYELIDS OPEN.
CALL MD @ ONCE. SKIN:IMMED FLUSH W/H*2O FOR @ LST 15 MIN. FOR LG
SPLASH, FLOOD BODY UNDER SHOWER. CALL MD @ ONCE. INGEST:INDUCE
VOMIT. GIVE H*2O. CALL MD @ ONCE. INHAL:REMOVE TO FRESH AIR. TREAT
SYMPS. CALL MD @ ONCE. CAUTN:IF UNCON, HAVING TROUBLE BRTHG/IN
CONVLS, DO NOT INDUCE VOMIT/GIVE H*2O. NOTE TO MD:NO SPEC ANTIDOTE
KNOWN.(SUPDAT)
Fire Fighting
Flash Point Method:CC
Flash Point:54.0F,12.2C
Extinguishing Media:USE DRY CHEM, ALCOHOL FOAM, CO*2/OTHER EXTING AGENT
SUITABLE FOR CLASS B FIRES. USE H*2O TO COOL CNTNRS EXPOSED
(SUPDAT)
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:TREAT LIKE AN ALCOHOL FIRE, FLAMMABLE
LIQUID.
Accidental Release
Spill Release Procedures:SMALL LIQUID SPILLS:CONTAIN W/ABSORBANT
MATERIAL, SUCH AS CLAY, SOIL OR ANY COMMERCIALLY AVAILABLE
ABSORBANT. COMBINE W/IGNITABLE PLANT WASTES. KEEP SPILL AWAY FROM
HEAT, SPARKS, FLAMES & WELDING OPER ATIONS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:KEEP AWAY FROM HEAT, SPARKS & OPEN
FLAME. MAY CAUSE EYE & SKIN IRRIT. AVOID CONTACT W/SKIN & EYES.
AVOID BREATHING VAPORS. DO NOT TAKE INTERNALLY.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:RESPIRATORY PROTECTION IS NOT NORMALLY NEEDED.
USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF
CONCERN .
Ventilation:GEN VENT IS RECOM. ADDNLY, LOC EXHST VENT IS RECOM WHERE
VAPS, MISTS OR AEROSOLS MAY BE RELEASED.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:AVAILABILITY OF EYE WASH FOUNTAIN & SAFETY
SHOWER IS RECOMMENDED.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXTING MEDIA:TO FIRE. FOR LG FIRES, USE H*2O SPRAY/FOG, THORO DRENCHING
BURNING MATL. MATLS TO AVOID:PERMANGANATES)WHICH CAN GENERATE HEAT,
FIRES, EXPLOS & RELEASE OF TOX FUMES. FIRST AID PROC:BASED O N
INDIVIDUAL RXNS OF PATIENT, MD'S JUDGMENT SHOULD BE USED TO CONTROL
SYMPS & CLINICAL CNDTN.
Chemical Properties
HCC:F3
Solubility in Water:SOLUBLE
Appearance and Odor:DARK GREEN LIQUID; ALCHOHOL ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
AVOID CNTCT W/STRONG OXIDIZERS (EG. CHLORINE, PEROXIDES, CHROMATES,
NITRIC ACID, PERCHLORATES, CONC O*2, (SUPP DATA)
Stability Condition to Avoid:DO NOT STORE NEAR IGNITION SOURCES.
Hazardous Decomposition Products:IN EVENT OF COMBUSTION CO, CO*2 MAY BE
FORMED. DO NOT BREATHE SMOKE OR FUMES.
Disposal
Waste Disposal Methods:IF PROD BECOMES WASTE, IT MEETS CRITERIA OF HAZ
WASTE AS DEFINED UNDER RCRA 40CFR261. COMBINE W/OTHER PLANT
IGNITABLE WASTES FOR DISP. CAN BE INCIN I/A/W LOC, STATE & FED
REGS. EMPTY PROD CNTNRS SHOUL D BE PUNCTURED, IF PLASTIC & PLACED
IN (INGRED 2)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.